259
UPS
By enabling the UPS (Uninterruptible Power Supply) support, you can protect your
NVR from abnormal system shutdown caused by power disruption. In the event of a
power failure the NVR will shut down automatically or enter auto-protection mode
by probing the power status of the connected UPS unit.
Standalone mode – USB
To operate under USB standalone mode, follow the steps below:
Plug in the USB cable on the UPS to the NVR.
Select the option “Enable UPS Support”.
Choose between whether the NVR will shut down or enter auto-protection mode
after AC power fails. Specify the time in minutes that the NVR should wait before
executing the option you have selected. After the NVR enters auto-protection
mode, the NVR resumes the previous operation status when the power restores.
Click “Apply All” to confirm.
Standalone mode – SNMP
To operate under SNMP standalone mode, follow the steps below:
Make sure the NVR is connected to the same physical network as the